Replaced shutter on ISCEX

FRS34149

Camilla and I removed the broken Model#VS35S2T0 Serial#3179 shutter and replaced it with Model#VS14S2T0 Serial#8796. The replacement unit had a slightly smaller outer diameter so we traded some posts with beam dumps that were on the side of the table not in use to get the correct height.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 11:14, Thursday 22 May 2025 (84542)
Both old and new models VS14 and VS35 use the same blade material (teflon coated SS) and have the same the max allowed energy density of <100mW/mm2 (https://www.uniblitz.com/blade-options/).
From D1800270 we expect the beam to be 14mW with a waist r=250um near the shutter, this gives an energy density of 70mW/mm2, which is within the shutter's specs.