Reports until 15:01, Thursday 22 May 2025
H1 DetChar (DetChar)
ansel.neunzert@LIGO.ORG - posted 15:01, Thursday 22 May 2025 (84546)
Line at 1028, 1038, 1048 etc Hz

An apparent 10-Hz comb at 1028, 1038, 1048... Hz was spotted while updating the lines lists. The peaks are right on integer frequencies (to within a single bin in 7200s SFTs).

I took a closer look and found that it's actually a single line jumping around in the spectrum. Anybody recognize this?

The line can also be seen in H1:PEM-CS_MAG_EBAY_LSCRACK_Z_DQ. It seems like it started coupling to DARM after the O4a/b break.

Details:

History of the line in DARM:

Comparison of magnetometer and strain data (y-axis for all plots is frequency; label got cut off for some reason): 

Images attached to this report