Reports until 15:30, Tuesday 27 May 2025
H1 ISC
anthony.sanchez@LIGO.ORG - posted 15:30, Tuesday 27 May 2025 - last comment - 16:21, Tuesday 27 May 2025(84598)
Re-ran the Baffle Alignment scripts


Using measured BPD values to center TMSX.
Old offset pitch -103.65326174900454 and yaw -109.59859916373702
New offset pitch -103.26627128958745 and yaw -110.61350904364517
H1:SUS-TMSX_M1_OPTICALIGN_P_OFFSET => -103.26627128958745
H1:SUS-TMSX_M1_OPTICALIGN_Y_OFFSET => -110.61350904364517
Turning off the test offsets to TMSX. (should be P -33.7, Y 30.6)
H1:SUS-TMSX_M1_TEST_P => OFF: OFFSET
H1:SUS-TMSX_M1_TEST_Y => OFF: OFFSET
TMSX dither alignment finished!

 

 

H1:SUS-TMSY_M1_TEST_P_SW1 => 8
H1:SUS-TMSY_M1_TEST_P => OFF: OFFSET
H1:SUS-TMSY_M1_TEST_Y_SW1 => 8
H1:SUS-TMSY_M1_TEST_Y => OFF: OFFSET
Using measured BPD values to center TMSY.
Old offset pitch 70.32489020986209 and yaw -271.65020191924117
New offset pitch 69.49962062863868 and yaw -270.19192585472683
H1:SUS-TMSY_M1_OPTICALIGN_P_OFFSET => 69.49962062863868
H1:SUS-TMSY_M1_OPTICALIGN_Y_OFFSET => -270.19192585472683
Turning off the test offsets to TMSY. (should be P -40.9, Y -33.1)
H1:SUS-TMSY_M1_TEST_P => OFF: OFFSET
H1:SUS-TMSY_M1_TEST_Y => OFF: OFFSET
TMSY dither alignment finished!


Using measured BPD values to center ITMY.
Old offset pitch -23.142354669728046 and yaw -19.674065180798973
New offset pitch -20.272119056234136 and yaw -18.665526580652642
H1:SUS-ITMY_M0_OPTICALIGN_P_OFFSET => -20.272119056234136
H1:SUS-ITMY_M0_OPTICALIGN_Y_OFFSET => -18.665526580652642
Turning off the test offsets to ITMY. (should be P -17.4, Y 17.9)
H1:SUS-ITMY_M0_TEST_P => OFF: OFFSET
H1:SUS-ITMY_M0_TEST_Y => OFF: OFFSET
ITMY dither alignment finished!

 

Using measured BPD values to center ITMX.
Old offset pitch -90.91516651598735 and yaw 110.69384598631228
New offset pitch -96.51043250715529 and yaw 109.11219915612594
H1:SUS-ITMX_M0_OPTICALIGN_P_OFFSET => -96.51043250715529
H1:SUS-ITMX_M0_OPTICALIGN_Y_OFFSET => 109.11219915612594
Turning off the test offsets to ITMX. (should be P -25.9, Y -18.5)
H1:SUS-ITMX_M0_TEST_P => OFF: OFFSET
H1:SUS-ITMX_M0_TEST_Y => OFF: OFFSET
ITMX dither alignment finished!

 

Comments related to this report
anthony.sanchez@LIGO.ORG - 16:21, Tuesday 27 May 2025 (84600)

Back on May 23rd during the last Lock when we reached CARM_TO_REFL[409]
The H1:SUS-TMSY_M1_OPTICALIGN_P_OFFSET sliders were set to:
P: 67.186 ----------------------> 69.3 current value
Y: -268.879--------------------> -270.0

And H1:SUS-TMSX_M1_OPTICALIGN_P_OFFSET
P:-102.658 -------------------> -103.4
Y: -107.4882------------------> -110.4

H1:SUS-ITMY_M0_OPTICALIGN_P_OFFSET
P: -21.08 -----------------------> -20.3
Y: -19.532 ---------------------> -18.7

H1:SUS-ITMX_M0_OPTICALIGN_P_OFFSET
P:  -99.756 ---------------------> -96.5
Y: 108.6     ---------------------> 109.1

Images attached to this comment