Displaying report 1-1 of 1.
Reports until 11:40, Monday 11 November 2013
H1 SEI (SEI, SUS)
hugo.paris@LIGO.ORG - posted 11:40, Monday 11 November 2013 (8460)
BSC-ITMX - SUS WD connected

SUS WD were connected to BSC-ITMX model.

Every other BSC-ISI model has it implemented already: ETMX,BS,ITMY,ETMY. ITMY is slightly different than the other chambers - Should be adjusted before next phase of testing.
 
The simulink blocks used to monitor the payload state are not associated with a library. They were thus copied from h1isietmx.mdl into h1isiitmx.mdl. h1isiitmx.mdl was also cleaned up a bit (adjusted lines so they look straight and organized).
 
The BSC-ITMX was recompiled and restarted. The payoad monitor display of BSC-ITMX overview screen was used to check that SUS trips SEI correctly:
- PAYLOAD_MON rectagle turned from white to red with the update.
- Block turns greed when ITMX Suspension user WD are untripped.
- Block turns back to red when ITMX Suspension user WD are tripped.
 
The new version of h1isiitmx.mdl was commited under the SVN as revision #6244.
 
Work was performed under WP# 4259 which is now closed.
 
Note: It would be useful to have the payload state bit, which is sent by SUS, to also account for the SUS user dackill state, SUS master switch, and SUS Damping loops status.
Images attached to this report
Non-image files attached to this report
Displaying report 1-1 of 1.