anthony.sanchez@LIGO.ORG - posted 16:41, Tuesday 27 May 2025 (84603)
Tuesday Ops Day Shift report.

TITLE: 05/27 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 12mph Gusts, 5mph 3min avg
    Primary useism: 0.06 μm/s
    Secondary useism: 0.12 μm/s
SHIFT SUMMARY:
See alog from before lunch: 84591

Locking process was stopped at DRMI locking since we couldn't seem to get DRMI to lock.
But ALS locked super Quickly all day and had no issues Finding IR. 

The Baffle Dither Align Scripts we ran once in the morning.
After which we couldn't get locked past PRMI.
Jenne W. did some investigations into PRM, PRX & PRY OLTFs which Jenne W. has deemed "probably okay" in her soon to be written alog on the subject. 
After this a different Jennie Tried changing some of the gains for Mich, which did not help.
Then we re-ran the baffle scripts again.

H1 IFO STATUS: ...... Still stuggling to lock past PRMI.

LOG:   

Start Time System Name Location Lazer_Haz Task Time End
15:30 LASER LASER HAZARD LVEA LASER HAZARD LVEA IS LASER HAZARD (\u2310\u25a0_\u25a0) 07:26
15:31 ISC Camilla & Matt LVEA Yes ISCT1 green beam power measurements. 17:28
15:34 FAC Kim LVEA N Putting garb in receiving 15:52
15:35 FAC Chris LVEA, Ends X & Y N Various Famis tasks 17:16
15:47 SEI Jim, Mitchel, Randy EX N Wind Fence Work 19:33
16:05 FAC Kim EY, EX N Techical cleaning 17:03
17:05 VAC Travis LVEA Yes Turning valve on leak detector 19:05
17:07 EE Ken Remote N Quick work out at EY 18:21
17:08 CDS Dave Remote N Restarting Camera services. 18:57
17:11 EE Fil & Ken LVEA Roll up door N Clean up from cable work 17:46
17:29 FAC Eric Water tanks N Checking Fire pumps 17:54
18:53 VAC Gerardo LVEA yes Checking Annulus & VAC status 19:06
20:24 SQZ Camilla & Julia LVEA yes Turning on the SQZ laser 20:39
20:27 Tour Amber, Maggie  & Tours Control Room -> Overpass N Giving tours to MESA students. 20:27
22:10 Tour Matt, Julia, Caroline LVEA Yes Giving tour in LVEA 22:39
22:51 SQZ Camilla, Georgia, Kevin LVEA Yes SQZT7 work 00:51
23:08 VAC Gerardo LVEA Yes Annulus work 01:08
Displaying report 1-1 of 1.