Reports until 18:24, Tuesday 27 May 2025
H1 ISC
matthewrichard.todd@LIGO.ORG - posted 18:24, Tuesday 27 May 2025 (84608)
March 10th ISS Injection Measurement -- CARM Pole Estimation

M. Todd, C. Cahillane


Revisiting the dataset from the March 10th, 2025  intensity noise injections that I did, Craig and I re-did a CARM pole estimate as followed in alog 65093.

Results: we estimate the CARM pole to be 0.67 +/- 0.005 Hz.


Using the Transmitted ARM RIN channels transfer function from intensity noise, we can fit a 1/f line to the low-frequency portion to estimate the CARM pole.

The plots below show some slight variation between the different channels, but all consistently around 0.67 Hz CARM pole. I have yet to examine exactly what this means for our loss estimates.


Code:

The code used to make the below plots is found:

/ligo/gitcommon/iss_noise_measurements/carm_pole_plotting.py

List of Figures:

1. All together plot pdf with all transfer functions and CARM pole fits in one document
2. ISS RIN to TRX - A RIN and CARM pole fit
3. ISS RIN to TRX - B RIN and CARM pole fit
4. ISS RIN to TRY - A RIN and CARM pole fit
5. ISS RIN to TRY - B RIN and CARM pole fit

Non-image files attached to this report