Displaying report 1-1 of 1.
Reports until 09:51, Wednesday 28 May 2025
H1 SUS (ISC)
jeffrey.kissel@LIGO.ORG - posted 09:51, Wednesday 28 May 2025 - last comment - 11:41, Wednesday 28 May 2025(84620)
H1 SUS BS M3 to M2 Oplev Damping Loops' Impulse Response
J. Kissel

As we begin to investigate transient issues with the Beam Splitter where its sensors are reporting intermittent glitching that is spoiling DRMI locking, the optical lever damping loops are always an open question for me. 

Here's the impulse response of the filters, shown both as a normal time-series, which shows that most of the action happens within the first 0.2 seconds. I also show a semilogx plot of the time series to show the early magnitude of the response.

Finally, I attach a screenshot of which filters are on.
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 11:41, Wednesday 28 May 2025 (84628)
Here's the frequency response of the filters via Bode Plot.
Again the EPICs gain applied to these filters is 300x and 650x for pitch and yaw, respectively.
Images attached to this comment
Displaying report 1-1 of 1.