Sheila, Elenna
I have commissioned the DC centering on the POP X WFS. This uses DC6 pitch and yaw. I made OLG measurements of both loops, setting them to have a UGF around 0.5 Hz. I had to add additional loop gain to get this UGF, similar to the REFL WFS centering.
Measurements saved in [userapps]/asc/h1/templates/DC_centering
Sheila is adding this centering loop to the ISC_DRMI guardian to engage when we lock DRMI.
We should probably also add "PM1 [P/Y] clear" buttons to the DC centering page.
I also edited the ISC_DRMI guardian to clear teh PM1 suspension when it goes to Down.
These alogs also contain relevant information regarding the PM1/DC6 control:84610, 84623, 84579
History clear buttons added to DC Centering medm screen.