Reports until 13:38, Wednesday 28 May 2025
H1 ISC
elenna.capote@LIGO.ORG - posted 13:38, Wednesday 28 May 2025 - last comment - 14:15, Wednesday 28 May 2025(84629)
POP centering commissioned

Sheila, Elenna

I have commissioned the DC centering on the POP X WFS. This uses DC6 pitch and yaw. I made OLG measurements of both loops, setting them to have a UGF around 0.5 Hz. I had to add additional loop gain to get this UGF, similar to the REFL WFS centering.

Measurements saved in [userapps]/asc/h1/templates/DC_centering

Sheila is adding this centering loop to the ISC_DRMI guardian to engage when we lock DRMI.

We should probably also add "PM1 [P/Y] clear" buttons to the DC centering page.

I also edited the ISC_DRMI guardian to clear teh PM1 suspension when it goes to Down.

These alogs also contain relevant information regarding the PM1/DC6 control:84610, 8462384579

Images attached to this report
Comments related to this report
oli.patane@LIGO.ORG - 14:15, Wednesday 28 May 2025 (84637)

History clear buttons added to DC Centering medm screen.