S. Dwyer, R. Short
While in PREP_ASC_FOR_FULL_IFO this afternoon, Sheila and I re-phased REFL9 similar to Georgia's attempt in alog84646, but we think we had a better result this time, maybe because alignment is a bit better now.
SDFs of gains and new phasing screenshots are attached. Phasing template has been saved with updated references as /opt/rtcds/userapps/release/asc/h1/templates/phasing/phase_REFL9_mrtodd.xml