Reports until 08:30, Sunday 01 June 2025
H1 General
corey.gray@LIGO.ORG - posted 08:30, Sunday 01 June 2025 - last comment - 09:29, Sunday 01 June 2025(84695)
Straightforward Alignment (compared to yesterday morning)

Notes On Alignment:

1445-1523 Accidentally started "manual" alignment without selecting it in ISC LOCK (got through Input Align), so went back to down and at 1457 restarted a formal  Manual Initial Alignment (modified, where we only go to PRX_LOCKED for PRC).  Green Arms were much easier to lock this morning compared to yesterday morning---Since we were down over night, I tweaked up flashes in both arms by hand (especially making sure Y-arm's flashes were over 1.0).

Now waiting for DRMI to lock.

Comments related to this report
corey.gray@LIGO.ORG - 09:29, Sunday 01 June 2025 (84697)