Reports until 15:20, Tuesday 03 June 2025
H1 SQZ
camilla.compton@LIGO.ORG - posted 15:20, Tuesday 03 June 2025 (84762)
Added SCAN_SQZANG_KHZ state to SQZ_MANAGER to use with SRCL Offset FIS dataset

I changed that way that the SQZ_MANAGER SCAN_SQZANG gen state worked to now take a brms_channel argument. Nominally for SCAN_SQZANG_FDS this is SQZ-DCPD_RATIO_3_DB_MON which tunes the squeezing around the 350Hz BLRMS to give the max IFO range. This is not yet tested, changes in SQZ_MANAGER.py svn.

I added a new state SCAN_SQZANG_KHZ (state number 85) from FIS that uses SQZ-DCPD_RATIO_6_DB_MON to maximize sqz at high frequency ~1700Hz. It makes sure ASC is off before scanning angle and can be be used when we take a sqz data set with SRCL offset steps e.g.  83569 to make 83572 brontosaurus plots.

To take SRCL offset FIS dataset (e.g. 83569):

Take NLG back to nominal ~11, once done.