Reports until 10:47, Wednesday 04 June 2025
H1 CDS
david.barker@LIGO.ORG - posted 10:47, Wednesday 04 June 2025 (84791)
ISC_LOCK ADJUST_POWER state number reduced to stop false lock reporting

TJ, Dave:

The ADJUST_POWER state of the ISC_LOCK guardian node has been exercised recently during locking, with the unexpected consequence of various CDS system mis-interpreting this as entering/leaving nominal-low-noise. This is because this state's number is 1000, greater than NLN=600. For example, attachment shows CDS overview screen mistakingly showing models' SDF diffs in RED. Yesterday TJ reduced this state's number to 521, a number which wasn't available when this state was first created but has since become available (graph snippet shown).