TITLE: 06/09 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: n/a tonight
SHIFT SUMMARY:
LOG:
- 2310 Locking
- 0011 OMC Whitening & Cal Lines were turned off, so.....
- 0011 DARM OLG measurement run (elenna)
- 0024 LOCKLOSS
- 2340 Had trouble bring up the alog webpage (could bring up other CDS webpages (on my gc laptop and and
- 0009 Francisco out of PCal Lab
- 0024 Locking
- Ran check Mich Fringes + PRMI since DRMI was not great. Once PRMI locked, touched up with PRM since it is currently not used for ASC. DRMI then locked fine.
- Also, for this lock, Elenna guardianized ISC_LOCK to get H1
- 0134 OMC Whitening
- 0136 LOCKLOSS
- Game Plan For night:
- Want to run the Simulines calibration measurement as soon as H1 completes the NLN state---Last week, H1 would lose lock from simullines, so this is to see if there's still issue.
- If H1 makes it through simullines, check on SQZ. If SQZ has issues, contact Vicky for touch-up
- Once H1 is thermalized, run full suite of calibration measurements
- 0137 Next Lock
- spent time tweaking PRMI (instead of running a more full alignment); this eventually worked
- 0301 Max Power complete (So this is the "start time for thermalization" I thought I heard people say after 2hrs is fine for thermalization, but the wiki says 3hrs.
- 0309 OMC Whitening & waiting for violins to damp---so Calibration could be run
- 0320 Flipped sign on ITMx Mode13 gain to -0.2
- 0321 NLN (but not fully green due to OMC Whitening/rung up violins)
- 0511 LOCKLOSS!!! :(
- 0357-0421 SimuLines measurement started. This is not an "official" measurement because H1 is not thermalized. This is mainly to see if this measurement causes a locklosses as noted on Jun5 (alog 84834). This successfully completred measurement did NOT cause a lockloss.
- 0435 switch ITMy M5 from FM6+FM8+FM10, gain= 0.01 to (2W settings of) FM6+FM7+FM10, gain = 0.01 (because this mode was the only one increasing after about an hour into the lock.
- Ultimately saved these settings in the hopes of running over night (but we had a lockloss).
- 0526 Saved lscparams & LOADED ISC_LOCK and VIOLIN_DAMPING_STATES nodes.
- Taking ISC_LOCK to IDLE overnight because H1 has been requiring assistance for alignment of DRMI most of the day.