Randy, Ibrahim
Today, Randy an I fit checked the BBSS Structure Support Plate (D2500013) and the Lifting Bar Assembly (D1100802) for the BBSS.
Overall, everything fit. See pictures below. Some relevant notes:
- BBSS Sctructure Support Plate fits around the BBSS unobstructed (Only obstruction is the HRTS Homodyne which will not be there)
- Structure Support Plate also fits fully in the BBSS container (width of plate is 31.5" and width of container is 31.75" so 0.25" clearance total).
- Installed Helicoils (3/8-16 x1.5D) on the Support Plate
- Lifting Bar assembly mounts with the arms of the lift with no obstructions
- Lifting Bars also fit fully in the container (width of bar edges is 31.5" and width of container is 31.75"
- BBSS with side Vibration Absorbers do not fit within the container (2" too wide) so must be removed prior. This is the only thing we saw that needs to move.
- Confirmed the height at the lift point (and where the support plate lies) is sufficient for the BBSS height.