Displaying report 1-1 of 1.
Reports until 16:26, Tuesday 10 June 2025
H1 CAL (CAL)
anthony.sanchez@LIGO.ORG - posted 16:26, Tuesday 10 June 2025 (84949)
Surpise! Another Calibration Sweep! Well Thermalized

We heard you like Calibration sweeps with a Thermalized IFO... So we Thermalized your IFO and took a 3rd CAL sweep!

pydarm measure --run-headless bb
2025-06-10 15:33:52,565 config file: /ligo/groups/cal/H1/ifo/pydarm_cmd_H1.yaml
2025-06-10 15:33:52,573 available measurements:
  pcal: PCal response, swept-sine (/ligo/groups/cal/H1/ifo/templates/PCALY2DARM_SS__template_.xml)
  bb  : PCal response, broad-band (/ligo/groups/cal/H1/ifo/templates/PCALY2DARM_BB__template_.xml)
  sens: sensing function (/ligo/groups/cal/H1/ifo/templates/DARMOLG_SS__template_.xml)
  act1x: actuation X L1 (UIM) stage response (/ligo/groups/cal/H1/ifo/templates/SUSETMX_L1_SS__template_.xml)
  act2x: actuation X L2 (PUM) stage response (/ligo/groups/cal/H1/ifo/templates/SUSETMX_L2_SS__template_.xml)
  act3x: actuation X L3 (TST) stage response (/ligo/groups/cal/H1/ifo/templates/SUSETMX_L3_SS__template_.xml)
2025-06-10 15:33:52,574 measurement sequence:
2025-06-10 15:33:52,574   ['bb']
2025-06-10 15:33:52,606 ##########
2025-06-10 15:33:52,606 measurement: bb: PCal response, broad-band measurement
2025-06-10 15:33:52,606 measurement timestamp: 20250610T223352Z
2025-06-10 15:33:52,606 measurement template: /ligo/groups/cal/H1/ifo/templates/PCALY2DARM_BB__template_.xml
2025-06-10 15:33:52,606 measurement output: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20250610T223352Z.xml
2025-06-10 15:33:52,607 executing headless bb measurement...

...
~ computer noises ~
...

notification: end of measurement
notification: end of test
diag> save /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20250610T223352Z.xml
/ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20250610T223352Z.xml saved
diag> quit
EXIT KERNEL

2025-06-10 15:39:02,645 bb measurement complete.
2025-06-10 15:39:02,645 bb output: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20250610T223352Z.xml
2025-06-10 15:39:02,645 all measurements complete.


Simulines:

gpstime;python /ligo/groups/cal/src/simulines/simulines/simuLines.py -i /ligo/groups/cal/H1/simulines_settings/newDARM_20231221/settings_h1_20250212.ini;gpstime
PDT: 2025-06-10 15:40:08.872455 PDT
UTC: 2025-06-10 22:40:08.872455 UTC
GPS: 1433630426.872455
2025-06-10 22:40:09,675 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20250610T224009Z.hdf5
2025-06-10 22:40:09,690 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20250610T224009Z.hdf5
2025-06-10 22:40:09,695 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20250610T224009Z.hdf5
2025-06-10 22:40:09,702 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20250610T224009Z.hdf5
2025-06-10 22:40:09,718 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20250610T224009Z.hdf5
2025-06-10 22:40:09,718 | INFO | Overall driving parameters:
2025-06-10 22:40:09,718 | INFO | Preparing to scan the following sweeps ['DARM_OLGTF', 'PCALY2DARMTF', 'L1_SUSETMX_iEXC2DARMTF', 'L2_SUSETMX_iEXC2DARMTF', 'L3_SUSETMX_iEXC2DARMTF']

...
~ computer noises ~
...


2025-06-10 23:02:52,500 | INFO | Ending lockloss monitor. This is either due to having completed the measurement, and this functionality being terminated; or because the whole process was aborted.
2025-06-10 23:03:29,523 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20250610T224009Z.hdf5
2025-06-10 23:03:29,531 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20250610T224009Z.hdf5
2025-06-10 23:03:29,537 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20250610T224009Z.hdf5
2025-06-10 23:03:29,544 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20250610T224009Z.hdf5
2025-06-10 23:03:29,551 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20250610T224009Z.hdf5
PDT: 2025-06-10 16:03:29.690650 PDT
UTC: 2025-06-10 23:03:29.690650 UTC
GPS: 1433631827.690650

 

 

Images attached to this report
Non-image files attached to this report
Displaying report 1-1 of 1.