Sheila, Elenna, Camilla
Sheila was questioning if something is drifting for us to need an initial alignment after the majority of relocks. Elenna and I noticed that BS PIT moves a lot both while powering up /moving spots and while in NLN. Unsure from the BS alignment inputs plot what's causing this.
This was also happening before the break (see below) but the operators were similarly needing more regular initial alignments before the break too. 1 year ago this was not happening, plot.
These large BS PIT changes began 5th to 6th July 2024 (plot). This is the day shift from the time that the first lock like this happened 5th July 2024 19:26UTC (12:26PT): 78877 at the time we were doing PR2 spot moves. There also was a SUS computer restart 78892 but that appeared to be a day after this started happening.
Sheila, Camilla
This reminded Sheila of when we were heating a SUS in the past and causing the bottom mass to pitch and the ASC to move the top mass to counteract this. Then after lockloss, the bottom mass would slowly go back to it's nominal position.
We do see this on the BS since the PR2 move, see attached (top 2 left plots). See in the green bottom mass oplev trace, when the ASC is turned off on lockloss, the BS moves quickly and then slowly moves again over the next ~30 minutes, do not see simular things on PR3. Attached is the same plot before the PR2 move. And below is a list of other PR2 positions we tried, all the other positions have also made this BS drift. The total PR2 move since the good place is ~3500urad in Yaw.
To avoid this heating and BS drift, we should move back towards a PR2 YAW of closer to 3200. But, we moved PR2 to avoid the spot clipping on the scrapper baffle, e.g. 77631, 80319, 82722, 82641.
I did a bit of alog archaeology to re-remember what we'd done in the past.
To put back the soft turn-off of the BS ASC, I think we need to:
Camilla made the good point that we probably don't want to implement this and then have the first trial of it be overnight. Maybe I'll put it in sometime Monday (when we again have commissioning time), and if we lose lock we can check that it did all the right things.
I've now implemented this soft let-go of BS pit in the ISC_DRMI guardian, and loaded. We'll be able to watch it throughout the day today, including while we're commissioning, so hopefully we'll be able to see it work properly at least once (eg, from a DRMI lockloss).
This 'slow let-go' mode for BS pitch certainly makes the behavior of the BS pit oplev qualitatively different.
In the attached plots, the sharp spike up and decay down behavior around -8 hours is how it had been looking for a long time (as Camilla notes in previous logs in this thread). Around -2 hours we lost lock from NomLowNoise, and while we do get a glitch upon lockloss, the BS doesn't seem to move quite as much, and is mostly flattened out after a shorter amount of time. I also note that this time (-2 hours ago) we didn't need to do an initial alignment (which was done at the -8 hours ago time). However, as Jeff pointed out, we held at DOWN for a while to reconcile SDFs, it's not quite a fair comparison.
We'll see how things go, but there's at least a chance that this will help reduce the need for initial alignments. If needed, we can try to tweak the time constant of the 'soft let-go' to further make the optical lever signal stay more overall flat.
The SUSBS SDF safe.snap file is saved with FM1 off, so that it won't get turned back on in SDF revert. The PREP_PRMI_ASC and PREP_DRMI_ASC states both re-enable FM1 - I may need to go through and ensure it's on for MICH initial alignment.
RyanS, Jenne
We've looked at a couple of times that the BS has been let go of slowly, and it seems like the cooldown time is usually about 17 minutes until it's basically done and at where it wants to be for the next acquisition of DRMI. Attached is one such example.
Alternatively, a day or so ago Tony had to do an initial alignment. On that day, it seemed like the BS took much longer to get to its quiescent spot. I'm not yet sure why the behavior is different sometimes.
Tony is working on taking a look at our average reacquisition time, which will help tell us whether we should make another change to further improve the time it takes to get the BS to where it wants to be for acquisition.