TITLE: 06/12 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 144Mpc
OUTGOING OPERATOR: Ibrahim
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 6mph Gusts, 4mph 3min avg
Primary useism: 0.01 μm/s
Secondary useism: 0.11 μm/s
QUICK SUMMARY:
H1 is still locked and has been for 5 hours and 45 minutes.
But the DCPDs are diverging again, Like there is some sort of Roll mode ring up again.
Turns out its the Same Roll mode from yesterday. I applied the same gain from yesterday to the roll mode and it has turned around immediately. I have accepted this as an SDF Diff so we can stay observing.
GRB-Short E573164 @ 1454 UTC stand down
it has been requested of me to run the PSAMS script if we were still locked this morning. Camilla just walked and I her and I will start working on PSAMs when the Stand Down ends.
Dropped out of Observing for Commissioning at 15:51UTC. Optimistic plan for commissioning time today: