Reports until 13:40, Friday 13 June 2025
H1 AOS
keita.kawabe@LIGO.ORG - posted 13:40, Friday 13 June 2025 - last comment - 23:25, Wednesday 18 June 2025(85019)
ISS 2nd loop assembly S1202966 inspection: No damage, but no upgrade parts, no cover/lid (JennieW, Keita)

Summary of (our knowledge about) 2nd loop array units are available on DCC: https://dcc.ligo.org/LIGO-D1101059

We opened the container of S1202966 in the optics lab for inspection. This is a unit removed from LHAM2 in 2016.

We found no damage (1st picture), all photodiodes and the QPD look OK, no chipping of the optics, but many components are missing.

I decided to disassemble the damaged/contaminated S1202967 partially to send some of the parts to C&B and keep them as the last-resort spares. Jennie sent the following parts to C&B. There are deep scuffs which should be the result of repeated metal-to-metal contact/scratching, but they should be OK for use once they go through C&B.

ISS array cover might be salvageable but the place where the poles are attached is bent so badly, bending it back might break it. See the 2nd picture, the surface is supposed to be flat.

Images attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 23:25, Wednesday 18 June 2025 (85175)

Brief update about the following two items. No spare was found at LHO as of Jun/18/2025, so in the worst case we will use the parts salvaged from the damaged  S1202967 assembly (they were already sent to C/B).

  • D1300718. This is a kit comprising two 4.501" poles with cutout (Type 1), one 6.511" pole (Type 2) and two thinner 3" poles (Type 3).
    • Total of 10 Type 1, 8 Type 2 and 10 Type 3 have been manufactured (ICS record) enough to manufacture 5 kits.
    • One kit is in WHAM2, one in LHAM2, one in the damaged S1202967, there might be another one for India unit S1202968, that's 4 kits in total maximum. There should be at least one spare kit somewhere.
  • D1300719. This is called QPD MT PLATE, it's a top platform to mount the QPD as well as the ISS array cover assembly.
    • Total of 8 has been manufactured (ICS record).
    • Like D1300718, 3 or 4 pieces were used (WHAM2, LHAM2, damaged S1202967, maybe one in India unit S1202968). There should be at least 4 spare pieces somewhere.