ITMx MODE13

Before going back to bed, wanted to check violins, and noticed that ITMx MODE13 was ringing up again.  I'm guessing the settings RyanC had going were not being used.  So, I put in what RyanC had 2hrs ago for the last lock, and within 2min, it quickly damped out the rung up MODE13.

I have NOT made a change/updated lscparams.

NEW Settings

ITMx MODE13:  FM1 + FM4 + FM10 + gain = -0.2

OLD Settings:

ITMx MODE13:  FM1 + FM2 + FM4 + FM10 + gain = 0.0

OK, going back to bed.  Sleep...we'll see.