Displaying report 1-1 of 1.
Reports until 14:16, Sunday 15 June 2025
H1 General
ryan.short@LIGO.ORG - posted 14:16, Sunday 15 June 2025 - last comment - 15:38, Sunday 15 June 2025(85057)
Lockloss @ 20:52 UTC

Lockloss @ 20:52 UTC after just under 15 hrs locked - link to lockloss tool

No obvious cause.

Comments related to this report
ryan.short@LIGO.ORG - 15:38, Sunday 15 June 2025 (85058)

Ran an initial alignment doing PRC align by hand, then main locking was fully automatic.

Once at low noise and before observing, I noticed SQZ looked poor, and the SQZ BLRMs were worse than at the start of the last lock stretch. I cycled SQZ_MANAGER through 'SCAN_SQZANG_FDS' to try and find a better SQZ angle, but the Guardian wasn't able to find a place that made the BLRMs and BNS range both look good, so I manually searched around at different angles and eventually settled on 139 with a "cleaned" range of 153Mpc. Started observing at 22:34 UTC.