Reports until 13:36, Monday 16 June 2025
H1 AOS
robert.schofield@LIGO.ORG - posted 13:36, Monday 16 June 2025 - last comment - 16:30, Monday 16 June 2025(85084)
Recommended CP Y offsets: -300 pitch, 300 yaw

Alenna noted that we will have CP-Y spots on the ballast baffle even when the CP is propertly aligned (which is why we eventually want to remove/fix the baffle), so I swept the CP in pitch and yaw and found a minimum in scatter coupling at about -300 p, 300 y.  The varying noise from the pump on HAM1 interfered with the measurement, so I think I can further minimize the coupling once the pump is off.

Comments related to this report
ryan.short@LIGO.ORG - 16:30, Monday 16 June 2025 (85100)OpsInfo

Accepted in SAFE and OBSERVE SDF tables as Robert left them. This new position has been causing ITMY saturations during LOWNOISE_COIL_DRIVERS due to the increased drive from the DAC, but this doesn't seem to be causing any noticeable locking issues.

Images attached to this comment