Safe SDF reconciliation

In preparation for the RCG upgrade, we are using the relocking time to reconcile SDF differences in the SAFE file.

Here are some of mine:

I have also determined that the unmonitored channel diffs in the LSC, ASC, and OMC models are guardian controlled values and do not need to be saved.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 15:29, Monday 16 June 2025 (85094)

Not accepting or reverting the h1sqz, h1ascsqzfc, or slow controls cs_sqz sdfs, attached. As these have the same observe and safe files.

Images attached to this comment
camilla.compton@LIGO.ORG - 15:35, Monday 16 June 2025 (85095)

Accepted  H1:TCS-ETMX_RH_SET{LOWER,UPPER}DRIVECURRENT as  ndscope-ing shows they are normally at this value.

Images attached to this comment
elenna.capote@LIGO.ORG - 17:00, Monday 16 June 2025 (85103)

Some of these SDFs may have then led to diffs in the OBSERVE state. I have reverted the roll mode tRamp, and accepted the OSC gains in the CAL CS model.

Images attached to this comment
oli.patane@LIGO.ORG - 17:03, Monday 16 June 2025 (85104)

I updated the OPTICALIGN OFFSETs for each suspension that we use those sliders on. I tried using my update_sus_safesnap.py script at first, but even though it's worked one other time in that past, it was not working anytime I tried using it on more than one suspension at a time (it seems like it was only doing one out of each suspension group). I ended up being able to get them all updated anyway eventually. I'm attaching all their sdfs and will be working on fixing the script. Note that a couple of the ETM/TMS values might not match thesetpoint exactly due to the screenshots happening during relocking and after they had moved a bit with the WFS