Reports until 10:01, Tuesday 17 June 2025
H1 CDS
david.barker@LIGO.ORG - posted 10:01, Tuesday 17 June 2025 - last comment - 16:37, Tuesday 17 June 2025(85120)
RCG5.5.0 completed 09:51

We have completed the upgrade of H1 frontends to RCG5.5.0 at 09:51.

Detailed alog will be written but surprises found/re-remembered:

EX dolphin frontends need to enable an unused port on the EY switch because the EX switch has no port control (damaged in Apr power outage)

PSL DBB model had an obsolete Dolphin IPC sender back when it used to have a dolphin card. New RCG doesn't allow senders with no cards. Removed the sender from the model, a DAQ restart is pending for this model

We had upgraded h1omc0 to 5.5.0 some time ago, but the H1.ipc file had changed so it needed a restart. Prior to restart it was clobbering the SWWD IPCs between sush34 and seih23, seih45.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 11:20, Tuesday 17 June 2025 (85124)
Images attached to this comment
david.barker@LIGO.ORG - 16:37, Tuesday 17 June 2025 (85139)

Here is a rough squence of today's upgrade, all times local PDT

07:22 rebuild H1EDC.ini to convince outselves the first DAQ restart will be model changes only

07:43 h1cdsrfm powered down, this breaks the linkage between Dolphin locations

07:43 h1ecatmon0 upgrade (reboot)

07:45 Dolphin network manager started on h1vmboot5-5, causing the standard set of end station systems to crash (susey, seiey, iscey and susex). We PAUSE'd the remaining EX (iscex, seiex)

07:51 Reboot h1susaux[ex, ey, b123, h2, h34, h56] pem[mx, my] to upgrade them. susaux[h34, ey] got stuck and were power cycled via IPMI.

08:03 DAQ 0-leg restart for new INI files across the board.

08:18 DAQ 1-leg restart. At this point omc0, susaux's and pemmid have good DAQ data, everyone else has BAD DAQ data.

08:27 Power down EX machines, power up EY machines. SWWD IPCs working, Dolphin IPC checks out.

08:32 Power up EX machines, all at the same time because of the Dolphin switch issue. They do not start. After some head scratching we remembered that the startup sequence needs to activate a dolphin switch port, which cannot happen at EX because the switch is damaged. Work around is for all three EX front ends to switch an unused port on the EY switch. Once this was put into place the EX machines started without anyone having to drive to the end station.

08:55 Reboot h1psl0 to upgrade PSL models (no dolphin cards, more about this later...)

08:56 Power down all non-upgraded corner station machines (SUS+SEI+ASC+LSC+OAF) but not h1omc0 (more about this later..)

09:00 h1psldbb is not running. It has an obsolete Dolphin IPC sender part in the model but no Dolphin card. RCG5.5.0 does not allow this. Rebuild model sans IPC part, starts running. Note PSLDBB DAQ data is BAD from this point till the second DAQ restart.

09:10 First power up h1sush2b, h1seih16 for HAM1 SEI work. SWWD IPC between the two working well (well, for these two, more later...)

09:20 Power up all remaining corner station computers

09:30 Discover wierd SWWD IPC receive values for HAM3 and HAM4 (val should be 1.0, but is -0.002 or 0.000).

09:34 try restart h1iopsush34, IPC values still bad. But h1omc0 has not been restarted so its using the old IPC configuration and could be writing out-of-bounds

09:35 restart h1omc0 models, SWWD IPC errors are resolved

09:44 power up h1cdsrfm. First EX is PAUSE'd, EY and CS are fenced. long range dolphin starts with no issues. A new MEDM is generated from the new H1.ipc file.

09:51 Complete in 2 hours.