After today's commissioning and trouble shooting work we had a list of SDFs to address. Elenna and I both addressed these.
Elenna will add a comment to this alog with the SDFs she addressed.
I took care of the SDF Diff for SQZ ADF. Kevin Kuns noticed this channel was not restored to its OBSERVING value; he took it to 320, but SDF flagged this because it should actually be 322, so I REVERTed this channel (H1:SQZ-ADF_VCXO_CONTROLS_SETFREQUENCYOFFSET) to 322 (see attached).
I don't understand what the ALS diffs are, but I reverted them because I think they may have occurred because Sheila and I left the green shutters open today to check the offsets.
I reverted all CAL gain tramps. Francisco had changed them due to a test.
I also SFDed the REFLAIR gains as done in this alog 85201, but didn't take a screenshot.