Reports until 09:06, Tuesday 24 June 2025
H1 CDS
jonathan.hanks@LIGO.ORG - posted 09:06, Tuesday 24 June 2025 - last comment - 09:08, Tuesday 24 June 2025(85271)
WP 12570 Update digivideo servers with a new build of the pylon camera software (no application/server changes)

Per WP 12570 we stopped the cameras on h1digivdeo[45] and updated the pylon and pylon-camera-server software.  This was to bring in a fix in the pylon library for leaked file descriptors when a camera dropped and reconnected.

Last week we just restarted the software to close all the leaked file descriptors.  This should solve the problem.  This was not a feature update of the camera software, just a rebuild against a newer pylon library.

This was done 8:50-9:00am local time (16:00 UTC).

The procedure was to:

1. run apt-get update

2. stop all the camera processes via the management web page

3. run apt-get install pylon pylon-camera-server

4. restart all the camera processes via the management web page

5. spot check a few cameras to make sure things come back.

Comments related to this report
jonathan.hanks@LIGO.ORG - 09:08, Tuesday 24 June 2025 (85272)

For posterity, pylon was updated to 8.1.0 and pylon-camera-server was updated to 0.1.18