jeffrey.kissel@LIGO.ORG - posted 14:58, Tuesday 24 June 2025 (85289)
2025-06-24 Inventory of (UK Satamp) SUS Damping Loop Open Loop Gain TF Measurements
J. Kissel

In order to prepare for implementing ECR ECR E2400330 which improves the whitening within the UK sat amps to improve the OSEM signal chain's total sensor noise between 0.05 and 10 Hz (see CSWG:11249 for a model of the noise improvement), I want to be sure we have a up-to-date measurement of the damping loop's suppression. This is so it can be divided out from the estimate of sensor noise before vs. after the change. Also, in general, it's good it we have pre-tuned templates for open loop gain transfer functions, as they use a markedly different excitation than "standard" "health check" transfer functions because the excitation must go through the damping loop controller filter.

Note: if we compensate for the change in satamp frequency response well (with the anti-whitening filters in the OSEMINF banks), then the open loop gain / loop suppression / close loop gain should remain unchanged across the whitening filter change, so one we have these we shouldn't need to take them again (unless commissioning demands more changes to the filters). 

Since this kind of inventory is best done digitally for other folks reference and in case I have to delegate, I share it here. 
The following is a table of available and believed "should be the same as now" open loop gain TF templates and aLOGs for all suspensions with UK satellite amplifiers (and the Filter Cavity HSTSs FC1 and FC2 for good measure).
Where there isn't templates that are "still valid," I give a brief note as to why. 

Optic    aLOG             Templates                                                                                         Still Valid?        If not, why not?
ETMX M0  (n/a)            none                                                                                              NO                  *Never measured
ETMX R0  (n/a)            none                                                                                              NO                  *Never measured

ETMY M0  LHO:6933         2013-07-??_????_H1SUSETMY_M0_*_WhiteNoise_OLGTF.xml                                               NO                  *Way old, not enough DOFs
ETMY R0  LHO:68405        2023-04-04_1731_H1SUSETMY_R0_WhiteNoise_*_0p01to50Hz_OpenLoopGainTF.xml                           Yes                 *But would be good to remeasure w/ and w/o R0 tracking

ITMX M0  LHO:7720         2013-09-10_2306_H1SUSITMY_M0_[R,V]_WhiteNoise_OLGTF.xml                                           NO                  *Way old, not enough DOFs
ITMX R0  (n/a)            none                                                                                              NO                  *Never measured

ITMY M0  (n/a)            none                                                                                              NO                  *Never measured
ITMY R0  (n/a)            none                                                                                              NO                  *Never measured

TMSX     (n/a)            none                                                                                              NO                  *Never measured

TMSY     LHO:6654         2013-06-06_1511_H1SUSTMSY_M1_[L,P]_WhiteNoise_OLGTF.xml                                           NO                  *Only L and P measured
 
BS       LHO:71269        2023-07-12_2000_H1SUSBS_M1_CDBIOState_1_WhiteNoise_*_0p01to50Hz_OpenLoopGainTF.xml                Yes                 *Oplev Damping OFF
         LHO:71465        2023-07-18_1740_H1SUSBS_M1_CDBIOState_1_OLDampingON_WhiteNoise_*_0p01to50Hz_OpenLoopGainTF.xml    Yes                 *Oplev Damping ON

MC1      LHO:85291        2022-10-13_1900_H1SUSMC1_M1_CDBIOState_1_WhiteNoise_*_0p01to100Hz_OpenLoopGainTF_new.xml          Yes

MC2      LHO:85291        2022-10-13_1900_H1SUSMC1_M1_CDBIOState_1_WhiteNoise_*_0p01to100Hz_OpenLoopGainTF_new.xml          Yes

MC3      (n/a)            none                                                                                              NO

PRM      LHO:85292        2022-10-13_1900_H1SUSMC1_M1_CDBIOState_1_WhiteNoise_*_0p01to100Hz_OpenLoopGainTF_new.xml          NO                  *EPICs gains changed since

PR2      LHO:85292        2022-10-12_2020_H1SUSPR2_M1_CDBIOState_1_WhiteNoise_*_0p01to100Hz_OpenLoopGainTF_new.xml          NO                  *EPICs gains changed since

PR3      LHO:64152        2022-07-26_1820_H1SUSPR3_M1_WhiteNoise_*_0p02to50Hz_OpenLoopGainTF.xml                            Yes

SRM      LHO:85285        2025-06-24_1704_H1SUSSRM_M1_WhiteNoise_*_0p01to100Hz_OpenLoopGainTF.xml                           NO                  *EPICs gains changed since

SR2      LHO:65314        2022-10-13_1900_H1SUSMC1_M1_CDBIOState_1_WhiteNoise_*_0p01to100Hz_OpenLoopGainTF_new.xml          NO                  *EPICs gains changed since

SR3      LHO:85255        2025-05-21_1800_H1SUSSR3_M1_WhiteNoise_*_0p02to50Hz_OpenLoopGainTF.xml                            Yes

FC1      LHO:85290        2022-10-14_2330_H1SUSFC1_M1_CDBIOState_1_WhiteNoise_*_0p01to100Hz_OpenLoopGainTF_new.xml          Yes

FC2      (n/a)             none                                                                                             NO

OMC      LHO:60054        2021-09-28_1640_H1SUSOMC_M1_WhiteNoise_*_0p02to50Hz_OpenLoopGain_2014vs2021Designs.xml            Yes

IM1      LHO:64039        2022-07-19_H1SUSIM1_M1_WhiteNoise_*_OLG.xml                                                       Yes

IM2      LHO:64039        2022-07-19_H1SUSIM2_M1_WhiteNoise_*_OLG.xml                                                       Yes

IM3      LHO:64039        2022-07-19_H1SUSIM3_M1_WhiteNoise_*_OLG.xml                                                       Yes

IM4      LHO:64039        2022-07-19_H1SUSIM4_M1_WhiteNoise_*_OLG.xml                                                       Yes 

So -- to we really need to focus our measurement energy on the QUADs which have really never been characterized and the recycling cavity HSTS which have their EPICs gains changed in 2023.
The good news is that 2023 me tuned a full set of QUAD R0 open loop gain TF templates using ETMY, so these templates should be viable for both the rest of the R0 chains as well as the main chain with little-to-no tuning (assuming alignment biases are not eating up a different amount of DAC range).
That leaves on the TMTS not having tuned templates, so that's where we'll have to spend our tuning time.
We obviously have templates that will work for the missing / out-of-date HSTSs.

I'll begin the campaign during upcoming Tuesdays, in advance of making the ECR E2400330 change.
Displaying report 1-1 of 1.