WP12623 h1asc add fast channels to DAQ
Elenna, Dave:
A new h1asc model was rev-locked and installed. Four new fast DQ channels were added to the DAQ (channel, rate):
> H1:ASC-DC6_P_IN1_DQ, 256
> H1:ASC-DC6_P_OUT_DQ, 512
> H1:ASC-DC6_Y_IN1_DQ, 256
> H1:ASC-DC6_Y_OUT_DQ, 512
DAQ restart needed.
WP12570 Restart Digivideo Cameras with latest pylon
Patrick, Jonathan, Dave:
Jonathan updated pylon on h1digivideo[4,5,6] and restarted all the camera servers on these machines. This should fix the bug of stuck open files accumulating when the camera connection is interrupted.
No DAQ restart needed.
Add PID SMOO channels to vacuum SDF
Dave:
Prior to today's h0vacly restart I added the missing CP PID-control SMOO channels to the vacuum SDF monitor.req and safe.snap files. SDF was restarted 08:29. No DAQ restart needed.
WP12577, 12608, 12615 Upgrade LY Vacuum Controls
Janos, Gerardo, Patrick, Jonathan, Erik, Dave:
Patrick installed a new h0vacly system this morning. Main items are:
Pleae see Patrick's alog for details.
A extended DAQ restart was required, renaming Ion Pump raw minute trend files for uninterrupted lookback and construcing new PT100 (HAM1) raw minute trends following the upgrade of h0vaclx last Tuesday (17th June 2025).
DAQ Restart
Jonathan, Erik, Patrick, Dave:
Immediately following the restart of h1asc at 11:52, the DAQ was restarted using the following procedure:
It was at this late point that I remembered that the temporary H1 version of PT100B is no longer needed, and indeed this channel has no data following the removal of the PT100B Volts channel from h0vacly. However since it is still in the EDC, we need to continue running the temporary IOC until the next DAQ restart. I've removed it from edcumaster.txt as a reminder.
GPS Leap Seconds Updates
Jonathan, Erik, Dave:
Erik's FAMIS task reminded us that the leapseonds files expiration date of 30 June 2025 is rapidly approaching. Although no leap seconds are to be applied, the files need to be updated to reset their expiration dates. Please see Erik and Jonathan's alog for more details.
DNS testing
Erik:
ns1 (backup DNS server) was used by Erik to see if we can reproduce the error whereby loss of connection to GC caused internal CDS name resolution issues. It did not.
Vacuum Ion Pump channel name changes (old-name, new-name)