Displaying report 1-1 of 1.
Reports until 19:39, Monday 30 June 2025
H1 General
anthony.sanchez@LIGO.ORG - posted 19:39, Monday 30 June 2025 - last comment - 16:58, Wednesday 02 July 2025(85447)
PCAL Lab TX module Maintenance complete

On Friday Jun 27th Francisco and I went to the the PCAL lab and did a PCAL TX module maintenance according to T1600436.
AOM alignment was touched up

Results:

Laser SN05  
Date June-26-2025
Laser Shutter Check Fail
Max OFS Offset 7.2V
95% OFS Offset 6.84V
Operating OFS Offset 3.42V
Laser Output Power 1.97W
Rejected Laser Power 3.3mW
AOM Input Power 1.92W
Max Diffracted Power 1.23W
Un-Diffracted Power 0.500W
AOM Diffraction Efficiency 64%
AOM Rejected Power 3.3mW
TxPD Power 1.4mW
OFSPD Power 1.73mW
Outer Beam Power 294mW
Inner Beam Power 292mW
Output Beam Power Ratio 0.9932
OFS Gain 7.50V
OFS Phase Margin 43.7
ALOG  
Non-image files attached to this report
Comments related to this report
francisco.llamas@LIGO.ORG - 16:58, Wednesday 02 July 2025 (85515)

After the maintenance I tweeked the AOM to increase the diffraction efficiency. The nominally, the diffraction should be above 70% efficiency, which translates to 1.34 W from the *Maestro*. My procedure went as follows:

  1. Set the OFS offset to the recorded max: 7.2 V on V2 of the HP power supply on the upper right (when looking from the front)
    • Once the offset is set, block the beam (be safe!)
  2. Placed the high-power head (HPH) before the AOM on the Tx module
    • Zero-ed the readout and then unblock the beam.
    • Readout: 1.92 W (consistent with maintenace done the day before).
  3. Placed HPH before the wedged beamsplitter
    • Readout: 1.24 W (consistent with maintenace done the day before).
  4. So far, everything is consistent with the maintenance. We can now adjust the AOM.
    • The AOM is placed on a New port stage, following the documentation for this component, the bottom screws will adjust the Y axis (height) and the top screws will adjust the X axis (angle of incidence).
  5. Adjusted Y1 and Y2 -- bottom left and bottom right screws, respectively. A counter-clockwise adjustment of each screw, to about one turn, increased the output to 1.28 W.
  6. Adjusted X1 and X2 -- top left and right screws -- to reach 1.30 W. Fine adjustments could not get a higher output.
  7. Returned offset to operating value of 3.42 V on power supply.

AOM alignment increased the efficiency to 67%, a gain of 3%.

Displaying report 1-1 of 1.