Reports until 13:38, Tuesday 01 July 2025
H1 SUS
oli.patane@LIGO.ORG - posted 13:38, Tuesday 01 July 2025 (85471)
SUS OSEMINF compensation filter updated for BS, PRM, PR3, SRM, SR3

To finish off Fil's work for ECR E2400330 replacing the M1 satamps for BS, PRM, PR3, SRM, and SR3, I replaced FM1 in their OSEMINF filter banks from being z:p = 10:0.4 to z:p = 5.31:0.0969 to properly compensate for the new satamp. I've attached the filter file diffs for each suspension. They've all been loaded in.

Images attached to this report