Reports until 16:37, Tuesday 01 July 2025
H1 SUS
oli.patane@LIGO.ORG - posted 16:37, Tuesday 01 July 2025 - last comment - 15:34, Friday 11 July 2025(85485)
Satamp swap OSEM noise first looks

I ran my damp_regression_compare script (85369) on the suspensions that we swapped the satellite amplifiers for today, BS, PRM, PR3, SRM, and SR3. The results show a decrease in the OSEM noise of at least 2x!

Part of what the script does is save the channel data as a .mat file so it's quicker to run next time, so I'll post that as well as the results.

BS
Results: /ligo/svncommon/SusSVN/sus/trunk/BSFM/H1/BS/SAGM1/Results/allDampRegressCompare_H1SUSBS_M1_NoiseComparison_1435348334vs1435435046-1200.pdf
      r12374

Data: /ligo/svncommon/SusSVN/sus/trunk/BSFM/H1/BS/SAGM1/Data/dampRegress_H1BS_M1_1435348334_1200.mat
     /ligo/svncommon/SusSVN/sus/trunk/BSFM/H1/BS/SAGM1/Data/dampRegress_H1BS_M1_1435435046_1200.mat
    r12373

PRM
Results: /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM1/Results/allDampRegressCompare_H1SUSPRM_M1_NoiseComparison_1435348334vs1435435046-1200.pdf
      r12376

Data: /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM1/Data/dampRegress_H1PRM_M1_1435435046_1200.mat
     /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM1/Data/dampRegress_H1PRM_M1_1435348334_1200.mat
     r12375

PR3
Results: /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/PR3/SAGM1/Results/allDampRegressCompare_H1SUSPR3_M1_NoiseComparison_1435348334vs1435435046-1200.pdf
      r12380

Data: /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/PR3/SAGM1/Data/dampRegress_H1PR3_M1_1435348334_1200.mat
     /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/PR3/SAGM1/Data/dampRegress_H1PR3_M1_1435435046_1200.mat
     r12379

SRM
Results: /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SRM/SAGM1/Results/allDampRegressCompare_H1SUSSRM_M1_NoiseComparison_1435348334vs1435435046-1200.pdf
      r12378

Data: /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SRM/SAGM1/Data/dampRegress_H1SRM_M1_1435435046_1200.mat
    /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SRM/SAGM1/Data/dampRegress_H1SRM_M1_1435348334_1200.mat
    r12377

SR3
Results: /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/SR3/SAGM1/Results/allDampRegressCompare_H1SUSSR3_M1_NoiseComparison_1435348334vs1435435046-1200.pdf
      r12382

Data: /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/SR3/SAGM1/Data/dampRegress_H1SR3_M1_1435348334_1200.mat
    /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/SR3/SAGM1/Data/dampRegress_H1SR3_M1_1435435046_1200.mat
    r12381

Non-image files attached to this report
Comments related to this report
oli.patane@LIGO.ORG - 15:34, Friday 11 July 2025 (85696)

Since a few of the before times I picked for some of the suspensions were during times where they had ISC control on, I've rerun them with a better starting time where there was no ISC control

BS
Results: /ligo/svncommon/SusSVN/sus/trunk/BSFM/H1/BS/SAGM1/Results/allDampRegressCompare_H1SUSBS_M1_NoiseComparison_1435154988vs1435435038-1200.pdf
      r12436

Data: /ligo/svncommon/SusSVN/sus/trunk/BSFM/H1/BS/SAGM1/Data/dampRegress_H1SUSBS_M1_1435154988_1200.mat
     /ligo/svncommon/SusSVN/sus/trunk/BSFM/H1/BS/SAGM1/Data/dampRegress_H1SUSBS_M1_1435435038_1200.mat
     r12437

PRM
Results: /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM1/Results/allDampRegressCompare_H1SUSPRM_M1_NoiseComparison_1435154988vs1435435046-1200.pdf
      r12438
Data: /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM1/Data/dampRegress_H1SUSPRM_M1_1435435046_1200.mat
     /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM1/Data/dampRegress_H1SUSPRM_M1_1435154988_1200.mat

     r12438

SRM
Results: /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SRM/SAGM1/Results/allDampRegressCompare_H1SUSSRM_M1_NoiseComparison_1435154988vs1435435046-1200.pdf
      r12441
Data: /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SRM/SAGM1/Data/dampRegress_H1SUSSRM_M1_1435435046_1200.mat
    /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SRM/SAGM1/Data/dampRegress_H1SUSSRM_M1_1435154988_1200.mat

    r12441

Non-image files attached to this comment