Displaying report 1-1 of 1.
Reports until 00:16, Wednesday 02 July 2025
H1 General (ISC, SQZ, SUS)
oli.patane@LIGO.ORG - posted 00:16, Wednesday 02 July 2025 - last comment - 10:07, Wednesday 02 July 2025(85492)
Ops OWL Intervention: SDFs edition

H1 Manager called on me to help with a bunch of SDF diffs.

- Some ASC POP A offsets, which were accepted in safe earlier today (85490), so I went ahead and accepted them for Observe as well

- IMC PZT offset changes, which were made earlier when working on realigning the IMC (85476)

- ALSX camera offsets, which were changed earlier (85472)

- the SR3 and SRM dackill bypass times were lengthened temporarily for part of the work today, which I realize now should have been reverted oops need to fix when we're out of Observing tomorrow

- SQZ OPO servo's common board excitation had been left switched on (switch on the right from EXC A), so I just opened the switch

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 10:07, Wednesday 02 July 2025 (85500)

Reverted DAQ Kill Bypass times to their 1200 values (per Oli's note above).

Images attached to this comment
Displaying report 1-1 of 1.