WP 12655
ECR E2400330
Drawing D0901284-v5
Modified List T2500232
The following SUS SAT Amps were upgraded per ECR E2400330. Modification improves the whitening stage to reduce ADC noise from 0.05 to 10 Hz.
| Suspension | Old | New |
| ITMY MO | S1100071 | S1100155 |
| ITMY MO/RO | S1100150 | S1100175 |
| ITMY RO | S1100075 | S1100178 |
| ITMX MO | S1100163 | S1100136 |
| ITMX MO/RO | S1100147 | S1000275 |
| ITMX RO | S1100132 | S1100090 |
| SR2 TOP | S1100112 | S1000296 |
| SR2 TOP RT/SD | S1100121 | S1100067 |
F. Clara, J. Kissel, O. Patane, M.Pirello
ITMX ITMY Hardware Watchdog Countdowns, Test Mass Sat Amp swap-outs done in less than 20 minutes.