Reports until 14:19, Tuesday 15 July 2025
H1 SQZ
camilla.compton@LIGO.ORG - posted 14:19, Tuesday 15 July 2025 (85775)
SQZT7 Beam Profiling

Leo, Jennie, Camilla, WP 12677

Setup steps:

Opened up the back side of SQZT7 and used the Nanoscan beam profile to profile the SQZ beam in 5 points between the LPM and MR13 (layout D2000242) with the nominal PSAMS settings [ZM4 92V Strain 6.0, ZM5 109V Strain -0.4]. And repeated with PSAMS set to 0V,0V [ZM4 0V Strain 2.25, ZM5 0V Strain -5.4], results attached, Leo will analyze.

To change PSAMS to Voltage we wanted:

Before we went back to squeezing, reverted the PSAMS offsets and put the servos back on (after clearing their histories), reduded SEED power back down to 0.6mW, also adjusted waveplates for PUMP rejected power, disabled picos and turned off OPO EXC that the dither lock left on.

Non-image files attached to this report