Displaying report 1-1 of 1.
Reports until 10:18, Thursday 17 July 2025
H1 SQZ
camilla.compton@LIGO.ORG - posted 10:18, Thursday 17 July 2025 - last comment - 15:48, Friday 18 July 2025(85813)
SQZ Data Set

Matt, Sheila, Camilla,

Took data roughly following 83594 with more mid-sqz data points (adjusting sqz angle to every 50degrees or so looks good in one direction and around every 20degrees in the other direction).
DTT saved as /ligo/home/matthewrichard.todd/Templates/sqz/20250717_SQZdata.xml and screenshot attached.

Before we started we scanned the SQZ angle from 0 to 280deg using 'ezcastep H1:SQZ-CLF_REFL_RF6_PHASE_PHASEDEG -s '3' '+2,150'' to set it later for ADF plot attached, then we ran SCAN_ALIGNMENT_FDS, checked NLG, adjusted OPO temp. Starting angle at 141deg, SQZ_ANG_ADJUST changed it to 148deg.

Type Time (UTC) Angle DTT Ref Notes
FDS 15:51:00 - 15:54:00 (-)148.4 ref 1 FDS after scan alignment and sqz ang
No SQZ 15:54:30 - 16:02:00  N/A ref 0  
FIS Mean SQZ (no ADF) 16:04:00 - 16:07:00 N/A ref 2  
FIS 16:08:00 - 16:11:00 (-) 148 ref 3  
FIS Mid + SQZ (+50deg) 16:12:00 - 16:15:00 (-) 198 ref 4  
FIS Mid + SQZ (+100deg) 16:15:30 - 16:18:30 (-)248 ref 5  
FIS Mid + SQZ (+150deg) 16:24:00 - 16:27:00 (+)120 ref 6 Had to change sign here, think we are going the correct direction again.
FIS Mid + SQZ (+200deg) 16:27:30 - 16:30:30 (+)170 ref 7  
FIS Mid + SQZ (+250deg) 16:31:00 - 16:34:00 (+)220 ref 8  
ASQZ 16:36:30 - 16:39:20 (+)245 ref 9 Note we flipped sign in last 10sec of data so only have 2m50s here

FIS Mid - SQZ (-50deg)

16:40:30 - 16:43:30 (-)98 ref 10  
FIS Mid - SQZ (-100deg) 16:44:00 - 16:47:00 (-)48 ref 11 Note that we'd already gone over ASQZ here
FIS Mid - SQZ (-20deg) 16:48:00 - 16:51:00 (-)128 ref 12  
FIS Mid - SQZ (-75deg) 16:51:30 - 16:54:30 (-)73 ref 13  
ASQZ 16:55:30 - 16:58:30 (-)65 ref 14 ASQZ again at different SQZ angle (looks the same)
FIS Mid - SQZ (-35deg) 16:59:00 - 17:02:00 (-)113 ref15  
FDS Mid SQZ + 17:06:30 - 17:09:30 (-)203 ref16  
FDS Mid SQZ - 17:12:00 - 17:15:00 (-)120 ref17  
 
Checked the NLG with adjusting the OPO crystal temp the normal way, using the SEED beam.
OPO Setpoint Amplified Max Amplified Min UnAmp Dark NLG OPO Gain Note
80uW 0.0948 0.0023 0.00705 -2.24e-5 13.4 -8 With changing OPO temp
Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 10:41, Thursday 17 July 2025 (85819)

I took 5 minutes of no-sqz data at 524 kHz and saved the outputs as .gwf files in /ligo/home/elenna.capote/OMC_DCPD/251707-103227_xcorr_data

Displaying report 1-1 of 1.