Displaying report 1-1 of 1.
Reports until 08:39, Thursday 17 July 2025
H1 CAL
thomas.shaffer@LIGO.ORG - posted 08:39, Thursday 17 July 2025 - last comment - 09:16, Thursday 17 July 2025(85812)
Calibration Sweep 1500 UTC

We were locked for over 6.5 hours when the measurements were started.

Simulines start:

PDT: 2025-07-17 08:07:30.859380 PDT
UTC: 2025-07-17 15:07:30.859380 UTC
GPS: 1436800068.859380
 

Simulines end:

PDT: 2025-07-17 08:30:47.210989 PDT
UTC: 2025-07-17 15:30:47.210989 UTC
GPS: 1436801465.210989
 

Files:

2025-07-17 15:30:47,050 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_
SS/DARMOLG_SS_20250717T150731Z.hdf5
2025-07-17 15:30:47,058 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DA
RM_SS/PCALY2DARM_SS_20250717T150731Z.hdf5
2025-07-17 15:30:47,062 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_
L1_SS/SUSETMX_L1_SS_20250717T150731Z.hdf5
2025-07-17 15:30:47,067 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_
L2_SS/SUSETMX_L2_SS_20250717T150731Z.hdf5
2025-07-17 15:30:47,073 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_
L3_SS/SUSETMX_L3_SS_20250717T150731Z.hdf5
 

Images attached to this report
Non-image files attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 09:16, Thursday 17 July 2025 (85815)

Here is today's broadband compared with some recent calibration measurements.

Images attached to this comment
Displaying report 1-1 of 1.