IM trends

The IMs and MCs have been burtrestored to the automatically generated snap file from monday 11/11 at 20:00

Attached are 10 min trends of the IMs osem signals in the euler basis (Long/Pitch/Yaw) during alignment on monday, and today after restoring the snapfile.

picture 1 : Monday 11/11 from 19:50 to 20:00 PT

picture 2 : Today 11/14 from 10:20 to 10:30 PT

No major shift is seen when comparing both trends

Images attached to this report
Comments related to this report
cheryl.vorvick@LIGO.ORG - 06:13, Friday 15 November 2013 (8569)IOO

I've looked at the plots, and there is a huge shift of IM1, and shifts that are large on IM2 and IM4. The fact that I changed IM3 on Monday but it's not showing a change is troublesome.

IM1

Delta 800 pitch

Delta 50 yaw

 

IM2

Delta 115 pitch

Delta 10 yaw

 

IM3

Delta 0 pitch

Delta 0 yaw

 

IM4

Delta 70 pitch

Delta 0 yaw

 

The good alignment time is 5:09PST 11/11, or 1:09UTC 11/12.

To really be confident about your alignment now vs the alignment on Monday, you'll need to trend the alignment slider values, the alignment drive values, and the OSEM readings for 1:05-1:10UTC 11/12, and use that to compare the current IM positions.

arnaud.pele@LIGO.ORG - 15:02, Friday 15 November 2013 (8575)

[Cheryl Arnaud]

After talking with Cheryl, I attached, a more accurate comparison between two dates : monday 11/11 from 5pm to 6pm during good alignment and thursday during the night (11/15) from midnight to 1am (quieter environment) after the ISS work of thursday, with the restored alignment from monday.

screenshot 1 : position signals in um/urad in the euler basis monday

screenshot 2 : position signals in um/urad in the euler basis thursday night

screenshot 3 : alignment sliders values monday + volt monitor of 1 osem to prove signal is going through the actuation chain

screenshot 4 : alignment sliders values thursday night + volt monitor of 1 osem to prove signal is going through the actuation chain

We should worry if we were seeing a shif of the order of a mrad, which is far from being the case here.

Images attached to this comment
cheryl.vorvick@LIGO.ORG - 15:03, Friday 15 November 2013 (8582)IOO

IM1

delta of 80 (not 800) in pitch