Displaying report 1-1 of 1.
Reports until 11:58, Thursday 17 July 2025
H1 ISC
elenna.capote@LIGO.ORG - posted 11:58, Thursday 17 July 2025 - last comment - 15:38, Thursday 17 July 2025(85823)
Designed new CSOFT P low pass

Looking at the measurement of CSOFT from this alog, and also remembering that CSOFT P tends to be highly coherent with DARM from 10-15 Hz, I decided to make some adjustments to the CSOFT P lowpass filter that would both suppress noise around 10 Hz, and also maybe buy back some phase at 1 Hz. I designed a 7 Hz low pass filter with only 40 dB of attentuation. The current lowpass filter design has 60 dB of attenuation, which seems like overkill. I adjusted the low pass to be elliptic, low Q, which gives us back about 5 degrees of phase, but reduces the gain at 10 Hz and above by a factor of 10. I didn't get a chance to try it in lock, but I changed the guardian to engage this filter on the way up to NLN (line 3341 of ISC_LOCK). There will be an SDF diff. The new filter is in FM7, the old filter is in FM9.

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 15:38, Thursday 17 July 2025 (85832)

This has reduced the coherence of CSOFT P with DARM. The blue reference trace shows the coherence from last night, and the red live trace from our relock today with the new low pass.

Images attached to this comment
Displaying report 1-1 of 1.