(Probably Errant) Saturday H1 Calibration Measurement (broadband headless + simulines)

Summary

Measurement NOTES:

Attached is a screenshot of the Calibration Monitor, and unfortunately, I did not get to run a PyDarm Report.  I'm assuming this is due to my CTRL-C from the headleass measurement noted above.  Because, also at the end of this measurement, there was an SDF Diff also!  Luckily, Tony is here and he was able to take care of the SDF Diff.  The SDF was for PCAL Y (medm is SiteMap/CAL EY) , and it was related to the In-Loop (OFS) PD(H1:CAL-PCALY_OFS_PD_OUT16) being railed at -7.8.  Tony fixed this by toggling the Loop Enable Button (H1:CAL-PCALY_OPTICALFOLLOWERSERVOENABLE) to Off and then On.  This is all mentioned on the top of the PCal Known Issues wiki.

Once the SDF was cleared H1 was taken back to Observing, but there was discussion about trying to run the calibration again since L1 was still relocking.  Opted to not drop out of Observing for this since we were already out of Observing for over 30min.