Reports until 14:17, Sunday 20 July 2025
H1 ISC (FRS, ISC, OpsInfo)
corey.gray@LIGO.ORG - posted 14:17, Sunday 20 July 2025 - last comment - 14:21, Sunday 20 July 2025(85876)
More OMC High Voltage OMC Power Supply Weirdness

(Corey, Elenna [remote], Tony)

Recent Backstory Alogs:  

Today, while locking H1 noticed that we were stuck in PREP_DC_READOUT_TRANSITION.  DIAG_MAIN was mentioning an OMC issue.  OMC_LOCK guardian was in a loop of trying to sweep the PZT to FIND_CARRIER, but Elenna noticed that the PZT was not sweeping.  Then she remmebered the previous issues!  

(I was on the wrong trail, because I had assumed the SR3 change I made somehow was the cause of the issue---it was NOT.)

We still had the OMC_LOCK in a non-ISC_LOCK-managed AUTO state and we were not totally sure of how to have ISC_LOCK remanage OMC_LOCK.  Tony found a 2015 alog from Patrick which we used to get OMC_LOCK managed again.  H1 continued on and has been in OBSERVING.

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 14:21, Sunday 20 July 2025 (85877)FRS, OpsInfo

Added a new comment for today's HAM6 Power Supply Issue to the already-opened FRS Ticket 34433.