Displaying report 1-1 of 1.
Reports until 09:04, Tuesday 22 July 2025
H1 SUS
oli.patane@LIGO.ORG - posted 09:04, Tuesday 22 July 2025 (85906)
New OSEMINF gain calibration measurements taken for SR3

This is part of the work we are doing for the Estimator. As part of that work, we are finetuning the OSEMINF gains, which we did previously for SR3 (84298), but since we've swapped the satamps we want to check how different these new values will be compared to the current gains as well as the gains we found that last time.

I ran excitations through the H1:ISI-HAM5_ISO_{X,Y,Z} filter banks with the settings of:

Measurements can be found at /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/SR3/Common/Data/2025-07-22_1530_H1ISIHAM5_ST1_WhiteNoise_ISO_{X,Y,Z}_0p05to40Hz_calibration.xml, svn revision r12476.

Displaying report 1-1 of 1.