[ChrisW, Zach]
The OMC model has been genericized and exported to LHO from LLO. Here is a summary of what was done:
-
Following a change in the directory structure, the l1omc.mdl and associated files were moved from lsc/l1 to omc/l1
-
A library part was created for the OMC model (located in omc/common/models/omc.mdl) and l1omc.mdl now links to this
-
An h1omc.mdl was created by H1-ifying l1omc.mdl
-
Screens and scripts have been genericized and put in omc/common/medm and omc/common/scripts, respectively
-
An L1OMC.txt foton file was committed to the SVN in omc/l1/filterfiles/. It can be copied to omc/h1/filterfiles and renamed when this is desired.
-
An h1omc safe.snap was generated from an L1 snap. It is in omc/h1/burtfiles. This should be loaded manually with burtgooey, then makeSafeBackup should be used to create an initial local snap with the appropriate soft links, etc..
All the above is committed to the SVN and has been checked out at LHO.
As I understand, there is an RCG build directory issue that is currently preventing installation, but that should be cleared up shortly.