Displaying report 1-1 of 1.
Reports until 08:47, Wednesday 23 July 2025
H1 ISC (Lockloss)
camilla.compton@LIGO.ORG - posted 08:47, Wednesday 23 July 2025 - last comment - 17:00, Thursday 24 July 2025(85935)
Locklosses with YAW ASC Excursion

In 85846 on Friday 18th, Elenna notes a lockloss after YAW ASC excursion, we have been having very short locks and I see evidence of two more of these yaw excursion in the last 24 hours:

Seen in CSOFT, SRC1, PRC2 and mainly on the L2 stage of quads. In the last 1-2 seconds before LL.

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 17:48, Wednesday 23 July 2025 (85950)

The lockloss that Ryan S. reports as being from a sitewide power glitch in this alog had a similar behavior in the suspension channels and yaw loops. Apparently the power glitch that caused the lockloss also tripped the HEPI pumps, but I'm not sure how that relates to the control loop behavior. I'm not sure if this is useful to link with these other locklosses or not.

Generally, every yaw ASC loops sees this behavior, but it's hard to tell what is moving first, or the most, since the channels are not calibrated into useful units. As a note, the soft loops are not DC coupled, so I imagine they are just following the other loops. Our lockloss scopes plot the very slow ASC channels, so here is a faster plot of some of the ASC channels before one of these locklosses. The centering loop signals are moving away from zero, but not large enough that the beam is at the edge of the WFS.

I broke out my old TMS servo scope to see if we are being pulled off the TMS QPDs. Clearly the X TR B yaw signal is increasing, but it may be because it's trying to follow a large movement in the hard loops. TMS X yaw moves about 1 urad before the lockloss as well.

In the first yaw excursion lockloss Camilla notes above, the ETMX HEPI RZ appears to oscillate in the two seconds before lockloss. I don't see that in the other yaw excursion lockloss though.

Images attached to this comment
ryan.crouch@LIGO.ORG - 20:32, Wednesday 23 July 2025 (85955)

Both of these YAW ASC locklosses saw TMSX_Y start oscillating a few seconds before the lockloss.

Images attached to this comment
elenna.capote@LIGO.ORG - 17:00, Thursday 24 July 2025 (85976)

Follow up to add that although the lockloss that Ryan S noted on 7/13 had an ASC excursion, the TMSX yaw suspension did not have the similar strange behavior that these other few locklosses have (ndscope). It's possible that this TMSX yaw behavior is linked to the sat amp change on 7/15, 85770.

Images attached to this comment
Displaying report 1-1 of 1.