Reports until 09:19, Thursday 24 July 2025
H1 SQZ
camilla.compton@LIGO.ORG - posted 09:19, Thursday 24 July 2025 - last comment - 09:25, Thursday 24 July 2025(85957)
SQZ Dataset for 10kHz

Sheila, Camilla

Took data roughly following 83594 with the aim of saving H1:OMC-DCPD_524K_A2_IN1 data with the PD sum after TJ changed the matrix as in 85937.
DTT saved as /ligo/home/camilla.compton/sqz/templates/dtt/20250724_SQZdata.xml screenshot attached and /ligo/home/sheila.dwyer/Noise_Budget_repos/quantumnoisebudgeting/data_files/higher_order_modes_sqzdataset.xml screenshot attached.
Note that the calibration was pushed during this FIS Mid SQZ data so CAL_DELTAL should be taken with a grain of salt.
 
Type Time (UTC) Angle DTT Ref in SQZ DTT ref in HOM
No SQZ 15:20:00 -15:37:00 N/A ref 0 ref 0,1
FIS Mean SQZ (no ADF) 15:44:30 - 15:49:30 N/A ref 1 ref 2,3
FIS ASQZ 15:52:30 - 15:55:30 (+)245 ref 2 ref 4,5
FIS Mid + SQZ 15:57:00 - 16:00:00 (-) 260 ref 3 ref 6,7
FIS Mid - SQZ 16:30:00 - 16:03:30 (-) 110 ref 4 ref 8,9
FIS SQZ (tuned for high freq) 16:06:00 - 16:09:00 (-) 150 ref 5 ref 10,11
 
Checked the NLG with adjusting the OPO crystal temp the normal way, using the SEED beam.
OPO Setpoint Amplified Max Amplified Min UnAmp Dark NLG OPO Gain Note
80uW 0.09708 0.002293 0.007017 -2.58e-5 13.8 -8 With changing OPO temp
Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 09:25, Thursday 24 July 2025 (85960)

Sheila and Matt point out that the HOM at 5kHz and 10kHz are clear to see, see attached.

Images attached to this comment