kiwamu.izumi@LIGO.ORG - posted 09:44, Monday 18 November 2013 (8602)
lowered the threshoold for FSS trasnmitted light

[Sheila and Kiwamu]

 The FSS wasn't locking this morning, interrupting PMC's lock. Lowering PSL-FSS_RESONANT_THRES from 0.9 to 0.5 fixed the issue. The alignment on the FSS reflection camera looked bad. It has been unclear why the FSS alignment kept drifting in pitch.