WP 12696
ECR E2400330
Drawing D0901284-v5
Modified List T2500232
The following SUS SAT Amps were upgraded per ECR E2400330. Modification improves the whitening stage to reduce ADC noise from 0.05 to 10 Hz. The EY PUM and UIM SAT Amps were NOT upgraded.
| Suspension | Old | New | OSEM | 
| ETMY MO | S1100098 | S1100088 | F1F2F3SD | 
| ETMY MO/RO | S1100079 | S1100083 | RTLF/RTLF | 
| ETMY RO | S1100087 | S1000281 | F1F2F3SD | 
| TMSY | S1100172 | S1100148 | F1F2F3LF | 
| TMSY | S1100107 | S1100172 | RTSD | 
| MC1 | S1100128 | S1100118 | T1T2T3LF | 
| MC1/MC3 | S1000292 | S1000287 | RTSD/T1T2 | 
| MC3 | S1000297 | S1100119 | T3LFRTSD | 
F. Clara, J. Kissel, O. Patane, M. Pirello
Once the new satamps were installed, I ran the script satampswap_bestpossible_filterupdate_ECR_E2400330.py to update the compensation filters for these suspensions. These 'best possible' compensation gains come from the tests Jeff did on each satamp before installation, which are found in /ligo/svncommon/SusSVN/sus/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/.
My input and the corresponding output is below:
oli.patane@cdsws27:/ligo/svncommon/SusSVN/sus/trunk/Common/PythonTools$ py satampswap_bestpossible_filterupdate_ECR_E2400330.py -o TMSY ETMY_M0_R0
All updated filters grabbed for TMSY
TMSY M1 F1 compensation filter updated to zpk([5.3],[0.0969],1,"n")
TMSY M1 F2 compensation filter updated to zpk([5.28],[0.0964],1,"n")
TMSY M1 F3 compensation filter updated to zpk([5.2],[0.095],1,"n")
TMSY M1 LF compensation filter updated to zpk([5.26],[0.096],1,"n")
TMSY M1 RT compensation filter updated to zpk([5.17],[0.0945],1,"n")
TMSY M1 SD compensation filter updated to zpk([5.26],[0.0961],1,"n")
write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSTMSY.txt
Done writing updated filters for TMSY
All updated filters grabbed for ETMY
ETMY R0 F1 compensation filter updated to zpk([5.2],[0.0951],1,"n")
ETMY R0 F2 compensation filter updated to zpk([5.2],[0.0951],1,"n")
ETMY R0 F3 compensation filter updated to zpk([5.25],[0.0959],1,"n")
ETMY R0 SD compensation filter updated to zpk([5.35],[0.098],1,"n")
ETMY M0 F1 compensation filter updated to zpk([5.31],[0.0971],1,"n")
ETMY M0 F2 compensation filter updated to zpk([5.27],[0.0965],1,"n")
ETMY M0 F3 compensation filter updated to zpk([5.22],[0.0955],1,"n")
ETMY M0 SD compensation filter updated to zpk([5.17],[0.0946],1,"n")
ETMY M0 LF compensation filter updated to zpk([5.2],[0.0951],1,"n")
ETMY M0 RT compensation filter updated to zpk([5.28],[0.0965],1,"n")
ETMY R0 LF compensation filter updated to zpk([5.29],[0.0967],1,"n")
ETMY R0 RT compensation filter updated to zpk([5.26],[0.0962],1,"n")
write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSETMY.txt
Done writing updated filters for ETMY
All done! Remember to double check and load in the filters for ['TMSY', 'ETMY_M0_R0']
oli.patane@cdsws27:/ligo/svncommon/SusSVN/sus/trunk/Common/PythonTools$ py satampswap_bestpossible_filterupdate_ECR_E2400330.py -o MC1 MC3
All updated filters grabbed for MC1
MC1 M1 RT compensation filter updated to zpk([5.13],[0.0937],1,"n")
MC1 M1 SD compensation filter updated to zpk([5.25],[0.096],1,"n")
MC1 M1 T1 compensation filter updated to zpk([5.26],[0.0962],1,"n")
MC1 M1 T2 compensation filter updated to zpk([5.18],[0.0947],1,"n")
MC1 M1 T3 compensation filter updated to zpk([5.32],[0.0972],1,"n")
MC1 M1 LF compensation filter updated to zpk([5.12],[0.0938],1,"n")
write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSMC1.txt
Done writing updated filters for MC1
All updated filters grabbed for MC3
MC3 M1 T3 compensation filter updated to zpk([5.32],[0.0972],1,"n")
MC3 M1 LF compensation filter updated to zpk([5.19],[0.0949],1,"n")
MC3 M1 RT compensation filter updated to zpk([5.35],[0.0979],1,"n")
MC3 M1 SD compensation filter updated to zpk([5.19],[0.0949],1,"n")
MC3 M1 T1 compensation filter updated to zpk([5.31],[0.097],1,"n")
MC3 M1 T2 compensation filter updated to zpk([5.24],[0.0958],1,"n")
write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSMC3.txt
Done writing updated filters for MC3
All done! Remember to double check and load in the filters for ['MC1', 'MC3']
After this I loaded in these new filters.