Alexa, Kiwamu, Rich Did more in-vacuum installation work in HAM6. Tip/Tilts and Beam Diverters are all installed. The only remaining electrical devices to install are the Picomotors. It's getting a bit busy in there, and we didn't want to add more stuff without talking to the alignment folks. Dogged things down with one dog each anticipating they will be moved. ******USE CARE MOVING THE TIP/TILTS, I TOOK THE OPTICS OFF THEIR STOPS****** Missing a few key electronics items in the chain, so electrical checkout is still pending on all these items. Tip/Tilt OM1 Serial Number of Tip/Tilt stage - 002 External Cable Number 236 Flange D6-F10 Internal vacuum cable S1106728 Tip/Tilt OM2 Serial Number of Tip/Tilt stage - 004 External Cable Number 237 Flange D6-F11 Internal vacuum cable S1106834 Tip/Tilt OM3 Serial Number of Tip/Tilt stage - 033 External Cable Number 238 Flange D6-F12 Internal vacuum cable S1106830 Beam Diverter #1 (AS) Diverter Serial Number 012 Flange: D6-F8 External Cable 317 Internal Vacuum Cable (Flange to Table Bracket) S1202649 Short Cable (Bracket to Diverter) S1202732 Beam Diverter #1 (OMC REFL) Diverter Serial Number 019 Flange: D6-F9 External Cable 316 Internal Vacuum Cable (Flange to Table Bracket) S1202652 Short Cable (Bracket to Diverter) S1202730