HAM6 Electrical Components Installation
Alexa, Kiwamu, Rich

Did more in-vacuum installation work in HAM6.  Tip/Tilts and Beam Diverters are all installed.  The only remaining electrical devices to install are the Picomotors.  It's getting a bit busy in there, and we didn't want to add more stuff without talking to the alignment folks.  Dogged things down with one dog each anticipating they will be moved.

******USE CARE MOVING THE TIP/TILTS, I TOOK THE OPTICS OFF THEIR STOPS******

Missing a few key electronics items in the chain, so electrical checkout is still pending on all these items.

Tip/Tilt OM1
Serial Number of Tip/Tilt stage - 002
External Cable Number 236
Flange D6-F10
Internal vacuum cable S1106728

Tip/Tilt OM2
Serial Number of Tip/Tilt stage - 004
External Cable Number 237
Flange D6-F11
Internal vacuum cable S1106834

Tip/Tilt OM3
Serial Number of Tip/Tilt stage - 033
External Cable Number 238
Flange D6-F12
Internal vacuum cable S1106830

Beam Diverter #1 (AS)
Diverter Serial Number 012
Flange: D6-F8
External Cable 317
Internal Vacuum Cable (Flange to Table Bracket) S1202649
Short Cable (Bracket to Diverter) S1202732

Beam Diverter #1 (OMC REFL)
Diverter Serial Number 019
Flange: D6-F9
External Cable 316
Internal Vacuum Cable (Flange to Table Bracket) S1202652
Short Cable (Bracket to Diverter) S1202730