Reports until 08:14, Friday 01 August 2025
H1 SEI
oli.patane@LIGO.ORG - posted 08:14, Friday 01 August 2025 (86131)
Seismometer Mass Check Monthly FAMIS

Closes FAMIS#26504, last checked 85571

T240 (channels averaged between 2025-08-01 15:08:44 - 15:08:54 UTC)
Averaging Mass Centering channels for 10 [sec] ...
2025-08-01 08:08:54.266493

There are 12 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -1.424 [V]
ETMX T240 2 DOF Y/V = -1.323 [V]
ETMX T240 2 DOF Z/W = -0.982 [V]
ITMX T240 1 DOF X/U = -2.045 [V]
ITMX T240 1 DOF Z/W = 0.443 [V]
ITMX T240 3 DOF X/U = -2.17 [V]
ITMY T240 3 DOF X/U = -0.963 [V]
ITMY T240 3 DOF Z/W = -2.619 [V]
BS T240 1 DOF Y/V = -0.351 [V]
BS T240 3 DOF Z/W = -0.431 [V]
HAM8 1 DOF Y/V = -0.541 [V]
HAM8 1 DOF Z/W = -0.871 [V]


All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = -0.121 [V]
ETMX T240 1 DOF Y/V = -0.125 [V]
ETMX T240 1 DOF Z/W = -0.158 [V]
ETMX T240 3 DOF X/U = -0.094 [V]
ETMX T240 3 DOF Y/V = -0.182 [V]
ETMX T240 3 DOF Z/W = -0.111 [V]
ETMY T240 1 DOF X/U = -0.015 [V]
ETMY T240 1 DOF Y/V = 0.105 [V]
ETMY T240 1 DOF Z/W = 0.155 [V]
ETMY T240 2 DOF X/U = -0.123 [V]
ETMY T240 2 DOF Y/V = 0.156 [V]
ETMY T240 2 DOF Z/W = 0.02 [V]
ETMY T240 3 DOF X/U = 0.163 [V]
ETMY T240 3 DOF Y/V = 0.004 [V]
ETMY T240 3 DOF Z/W = 0.071 [V]
ITMX T240 1 DOF Y/V = 0.244 [V]
ITMX T240 2 DOF X/U = 0.164 [V]
ITMX T240 2 DOF Y/V = 0.252 [V]
ITMX T240 2 DOF Z/W = 0.218 [V]
ITMX T240 3 DOF Y/V = 0.104 [V]
ITMX T240 3 DOF Z/W = 0.117 [V]
ITMY T240 1 DOF X/U = 0.038 [V]
ITMY T240 1 DOF Y/V = 0.096 [V]
ITMY T240 1 DOF Z/W = -0.0 [V]
ITMY T240 2 DOF X/U = 0.022 [V]
ITMY T240 2 DOF Y/V = 0.244 [V]
ITMY T240 2 DOF Z/W = 0.089 [V]
ITMY T240 3 DOF Y/V = 0.044 [V]
BS T240 1 DOF X/U = -0.08 [V]
BS T240 1 DOF Z/W = 0.162 [V]
BS T240 2 DOF X/U = 0.068 [V]
BS T240 2 DOF Y/V = 0.161 [V]
BS T240 2 DOF Z/W = 0.027 [V]
BS T240 3 DOF X/U = -0.161 [V]
BS T240 3 DOF Y/V = -0.294 [V]
HAM8 1 DOF X/U = -0.216 [V]

 

STS (channels averaged between 2025-08-01 15:09:20 - 15:09:30 UTC)
Averaging Mass Centering channels for 10 [sec] ...

2025-08-01 08:09:30.264056
There are 2 STS proof masses out of range ( > 2.0 [V] )!
STS EY DOF X/U = -4.662 [V]
STS EY DOF Z/W = 2.344 [V]


All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.46 [V]
STS A DOF Y/V = -0.752 [V]
STS A DOF Z/W = -0.633 [V]
STS B DOF X/U = 0.163 [V]
STS B DOF Y/V = 0.96 [V]
STS B DOF Z/W = -0.374 [V]
STS C DOF X/U = -0.762 [V]
STS C DOF Y/V = 0.795 [V]
STS C DOF Z/W = 0.575 [V]
STS EX DOF X/U = -0.135 [V]
STS EX DOF Y/V = -0.089 [V]
STS EX DOF Z/W = 0.05 [V]
STS EY DOF Y/V = 1.196 [V]
STS FC DOF X/U = 0.198 [V]
STS FC DOF Y/V = -1.143 [V]
STS FC DOF Z/W = 0.603 [V]