betsy.weaver@LIGO.ORG - posted 12:57, Monday 08 April 2013 - last comment - 15:45, Friday 22 November 2013(5983)
B&K Hammered MC1, PR3, and PRM

After fixing any loose dog clamps, and retorquing, Arnaud and I took B&K hammer measurements of the HAM2 PR3, PRM, and MC1 this morning.  We still need to do PR2 and MC3 (which has a temp IO alignment mirror nestled up against it's structure).  We took PR3 and PRM data with vibration absorbers on and off.  We only took MC1 data with the vibration absorbers on since they were already on and are difficult to remove and then replace.  Plots and statements to come.

Comments related to this report
travis.sadecki@LIGO.ORG - 14:44, Monday 08 April 2013 (5988)

Arnaud and I snuck in and got B&K hammering done on PR2 before the transition to laser hazard.

arnaud.pele@LIGO.ORG - 13:51, Tuesday 09 April 2013 (6000)

Betsy and I hammered the last suspension missing in our list: MC3.

The results are coming soon

guido.mueller@LIGO.ORG - 11:45, Tuesday 19 November 2013 (8626)
Results are at alog 6014
jeffrey.kissel@LIGO.ORG - 15:45, Friday 22 November 2013 (8697)
LHO aLOG 6014 are different results -- from PR3, and they don't even include the results for that measurement. Arnaud and I will be processing and post all the B&K data from the HAM2, HAM3, and and BSC3 (ITMX) next week.